Model / Identity
YJ-FI310
Custom machine | Sample-confirmed
Screen thermal patterns after induction foil sealing, with project-specific alarm or rejection integration. Provide good and defective sample bottles, line speed and bottle spacing so blind tests can establish detectable defects and decision limits. Leak rate and seal strength require separate, appropriate tests.

Actual equipment photos from the factory. Confirm the final configuration with the containers, product, sample trials and agreed equipment scope.



Selection points
Start with the actual container, packaging material and process to define tooling, changeover and integration. Confirm cycle time through sample trials. Photos, videos or drawings are enough to start the discussion.
YJ-FI310
Sold independently; the inspection solution is customized to the container, foil and line.
To be confirmed by blind testing representative containers at the complete line speed.
Inline thermal acquisition and algorithmic decision with project-specific alarm or reject outputs.
Selection points
Provide the container, foil construction, normal and defective samples, line speed, spacing, ambient temperature and reject requirements. These inputs determine the field of view, triggering, sample library and acceptance method.
Selection points
YJ-FI310
Sold independently; the inspection solution is customized to the container, foil and line.
To be confirmed by blind testing representative containers at the complete line speed.
Inline thermal acquisition and algorithmic decision with project-specific alarm or reject outputs.
Containers using bottle-mouth induction foil seals; cap, mouth and foil structures to be confirmed.
To be confirmed from container geometry, mouth size, conveyor spacing and camera field of view.
Bottled products; product temperature and ambient thermal background must be evaluated.
Bottle-mouth foil seal assembly; material, construction and thermal response require sample review.
Thermal acquisition, feature analysis, anomaly decision, result recording and alarm/reject integration.
Camera field of view, trigger, shielding and conveyor locating are customized to the container and line.
Target defects may include missing or reversed foil, missing edges, damage, wrinkles, overheating, insufficient heating, skewed or loose caps and suspected weak seals; final classes follow the approved sample library.
Supplier speed and accuracy figures are not commitments; blind tests must quantify false rejects and misses.
Provide physical samples, dimensions and target requirements.
Confirm the process, locating, changeover and integration boundary.
Use representative samples to verify the result and complete cycle.
Approve the technical agreement, supply scope and quotation.
Configuration choice
Review machine structure, sample fit, changeover and adjacent-line interfaces before confirming the final configuration and acceptance method.
Inline thermal acquisition and algorithmic decision with project-specific alarm or reject outputs.
Camera field of view, trigger, shielding and conveyor locating are customized to the container and line.
Can interface with the downstream sealing line, PLC, alarm, reject and traceability system. To be confirmed by blind testing representative containers at the complete line speed.
Custom machine | Sample-confirmed
Selection points
No. Thermal patterns identify process and heat-distribution anomalies. Leak rate, peel force or seal strength still require the corresponding physical test.
Use blind trials with representative container types, good samples and defined defects. Report missed defects and false rejects separately at the agreed sample set and line speed.
Trigger, PLC, alarm, reject and traceability interfaces can be engineered, but the current line speed, spacing and control permissions must be reviewed.
Provide normal and defective samples, bottle-mouth and foil construction, real line speed, spacing, environment and alarm/reject acceptance requirements.
Send inspection samples
The machine is sold independently, while final configuration, specifications and acceptance method remain sample- and project-confirmed.